An Austrian customer approached Hotten for a custom USB cable with a strict weight limit per meter. The design called for shielding around each twisted pair and a separate shield around the entire cable. The customer will handle the certification required for its European defense project.
How do eight cores fit within an 8.0 mm cable diameter?
The cable uses three wire gauges. Two 26 AWG shielded twisted pairs and one 28 AWG shielded twisted pair account for six cores. Two individual 22 AWG wires make up the remaining cores. All eight use stranded tinned copper conductors with FEP insulation.
Each twisted pair has its own tinned copper braid with at least 90% coverage. Once laid together, the pairs and individual wires form a cable core with a nominal diameter of 6.2 mm. An overall tinned copper braid provides at least 85% coverage. PTFE binder tape and a black TPU outer jacket complete the cable, bringing its finished diameter to 8.0 ± 0.3 mm.
Cable specifications
Parameter |
Specification |
Weight per meter |
Customer target <97 g/m. Specification limit ≤97 g/m. |
Core configuration |
2 × 26 AWG pairs + 1 × 28 AWG pair + 2 × 22 AWG wires (8 cores) |
Conductor / insulation |
Stranded tinned copper / FEP |
Braid coverage |
≥90% on each twisted pair and ≥85% overall |
Outer jacket / cable diameter |
Black TPU, approx. 0.8 mm wall thickness. Finished OD 8.0 ± 0.3 mm. |
Characteristic impedance (2 ns) |
26 AWG pairs: 90 ± 7 Ω. 28 AWG pair: 90 ± 10 Ω. |
Max. conductor resistance at 20°C |
26 AWG: 154 Ω/km. 28 AWG: 256 Ω/km. 22 AWG: 80 Ω/km. |
Rated voltage / temperature |
30 V / 105°C |
Dielectric withstand |
500 V AC for 1 minute |
Insulation resistance at 20°C |
≥1,000 MΩ`km |
Why specify impedance separately for each pair type?
Both pair types have a nominal characteristic impedance of 90 Ω. The tolerance is ±7 Ω for the 26 AWG pairs and ±10 Ω for the 28 AWG pair. Listing them separately lets the customer check each pair against the correct range during sample evaluation. For the two individual 22 AWG wires, the specification gives a maximum resistance per conductor.
Custom USB cables and assemblies from Hotten
If your project has weight or space constraints, send Hotten your target weight per meter, maximum cable diameter, core configuration and electrical requirements. Our engineers can review the cable design. For a terminated USB cable assembly, include your drawing, finished length, connector part numbers and pinout so we can customize the cable and terminate both ends to your specifications.