132CX40AWG High Capacitance Handle Connection Cable Medical Ultrasound Probe Cable Assembly for B-ultrasound Inspection
| Procurement Item | Recommended Information |
|---|---|
| Application | Medical Ultrasound / B-Ultrasound |
| Cable Type | Ultrasound Probe / Handle Connection Cable Assembly |
| Core Count | 132C |
| Conductor Size | 40AWG |
| Conductor Material | Required material / plating |
| Capacitance | High-capacitance target and tolerance |
| Insulation | Required material |
| Shielding | Required shield structure |
| Cable Diameter | Target / maximum allowable OD |
| OD Tolerance | Required tolerance |
| Cable Length | Finished cable length |
| Flexibility | Bending / routing requirements |
| Connector | Probe-side / handle-side / equipment-side connector |
| Pinout | Channel and contact assignment |
| Termination | Required termination method |
| Drawing | Cable / assembly drawing |
| Prototype Quantity | Engineering sample quantity |
| Production Volume | Expected recurring volume |
| Testing | Capacitance, continuity, dimensional and mechanical requirements |
| Name | Material |
| Conductor | Silver plated copper |
| Tinned copper | |
| Silver plated copper alloy | |
| Tinned copper alloy | |
| Insulation | Teflon:PTFE/ePTFE/FEP/PFA |
| Shield | Tinned copper/Silver plated copper |
| CU/PET、 AL/PET | |
| Sheath | PFA/FEP/PTFE |
| Jacket | PVC/TPU/TPE/Silicone/PFA/FEP |
- Overview
- Recommended Products
Ultrasound signal channels
Power conductors
Ground / return conductors
Auxiliary channels
Shield / reference connections
Core grouping
Pin assignment
Conductor material
AWG
Plating
Stranding structure
Insulation
Electrical requirements
Flexibility requirements
Target capacitance
Capacitance per meter or total cable capacitance
Acceptable tolerance
Measurement conditions
Cable length
Channel-to-channel consistency
Required system-level electrical performance
Conductor configuration
Capacitance
Cable length
Insulation characteristics
Shielding
Channel consistency
Grounding
Connector termination
Probe interface
Target OD
Maximum allowable OD
OD tolerance
Probe routing clearance
Handle entry dimensions
Connector entry dimensions
Minimum bending radius
Strain relief
Static or dynamic bending
Minimum bending radius
Repeated movement
Probe handling conditions
Cable routing
Connector exit direction
Strain-relief requirements
Long-term flexibility requirements
Shielding type
Shield material
Shield coverage
Grounding method
Shield termination
Channel-to-channel isolation
Connector-side shield continuity
EMI requirements
Handle-side connector
Cable exit direction
Strain relief
Bend area near the handle
Available internal space
Connector locking mechanism
Cable length inside the handle
Connector manufacturer
Connector series
Part number
Contact count
Pitch
Pin assignment
Connector orientation
Mating interface
Termination method
Strain relief
Overmolding requirements, where applicable
Core count
AWG
Conductor material
Capacitance
Cable diameter
Cable length
Insulation
Shielding
Outer jacket
Connector
Pin assignment
Termination
Handle connection structure
Prototype samples
Mass-production configuration
Ultrasound probe application
132-core requirement
40AWG conductor requirement
Conductor material
High-capacitance target
Capacitance tolerance
Cable drawing
Target OD and tolerance
Insulation requirement
Shielding requirement
Cable length
Flexibility / bending requirements
Handle-side connector
Equipment-side connector
Pinout
Termination drawing
Prototype quantity
Expected production volume
Required testing
◆ 132 Core 40AWG Ultrasound Probe Cable Assembly
High Density Micro Coaxial Cable Solution for B-Ultrasound Systems
HOTTEN 132 Core 40AWG Ultrasound Probe Cable Assembly is designed for medical ultrasound probes and B-ultrasound inspection equipment requiring high-density signal transmission, reliable connection performance and customized cable structures.
With a multi-core micro coaxial cable design, this cable integrates numerous signal channels into a compact structure, helping medical equipment manufacturers achieve efficient signal transmission within limited installation space.
◆ Key Advantages
✓ 132 core high-density cable structure for multi-channel ultrasound signals
✓ 40AWG fine conductor design for compact medical applications
✓ Micro coaxial technology providing reliable signal transmission
✓ Excellent shielding performance to reduce electromagnetic interference
✓ Flexible structure suitable for ultrasound probe handle connection
✓ Customized cable assembly solutions available
◆ Product Features
High Density Signal Connection for Ultrasound Applications
Modern ultrasound equipment requires cables that can support multiple signal channels while maintaining stable electrical performance.
HOTTEN 132 Core Ultrasound Cable is developed with optimized:
● Fine conductor structure
● Insulation materials
● Shielding layers
● Cable arrangement technology
These designs help achieve:
✓ Stable signal transmission
✓ Compact cable diameter
✓ Reliable long-term operation
◆ Reliable Cable Structure for Medical Equipment
The 40AWG conductor design provides a balance between:
● Electrical performance
● Mechanical strength
● Cable flexibility
Combined with customized insulation and shielding materials, this cable can meet different requirements from ultrasound equipment manufacturers.
◆ Applications
This 132 Core 40AWG Ultrasound Cable is suitable for:
● B-ultrasound inspection systems
● Ultrasound probe assemblies
● Medical imaging equipment
● Diagnostic ultrasound devices
● Custom medical equipment
Engineering & Procurement Considerations
What Engineers Should Consider When Selecting a 132C 40AWG Ultrasound Probe Cable
A high-density ultrasound probe cable assembly connects the ultrasound transducer or probe with the supporting diagnostic equipment. For medical ultrasound systems, cable selection should balance high core count, fine-gauge conductors, capacitance, signal transmission, flexibility, cable dimensions and connector integration.
This configuration is defined by 132 cores, 40AWG conductors and a high-capacitance design, making the relationship between core count, electrical characteristics and mechanical construction particularly important during engineering development.
Key Engineering Requirements
| Engineering Requirement | Key Considerations |
|---|---|
| 132-Core Configuration | The 132 conductors should match the channel and electrical architecture of the ultrasound probe or transducer. |
| 40AWG Fine-Gauge Conductors | Fine-gauge conductors support high-density cable construction where installation space is constrained. |
| High Capacitance | The target capacitance should be defined according to the electrical requirements of the ultrasound system. |
| Signal Integrity | Conductor geometry, insulation, capacitance, shielding, cable length and termination should be evaluated together. |
| Compact Construction | Overall cable diameter should fit the probe, handle and equipment routing path. |
| Flexibility | Cable construction should support probe movement, handling and routing requirements. |
| Channel Consistency | High-core-count cables require consistent electrical and dimensional characteristics across channels. |
| Connector Compatibility | Probe-side and equipment-side connectors must match the required interface and pinout. |
| Manufacturing Consistency | Core order, electrical characteristics, OD and termination quality should remain stable during production. |
Published Product Configuration
| Item | Specification |
|---|---|
| Product Type | Medical Ultrasound Probe Cable Assembly |
| Application | B-Ultrasound / Ultrasound Probe Inspection |
| Core Configuration | 132C |
| Conductor Size | 40AWG |
| Cable Type | Handle Connection Cable |
| Electrical Characteristic | High Capacitance |
| Cable Structure | Multi-Core / Probe Cable Assembly |
| Cable Length | Customized |
| Cable Diameter | Customized |
| Connector / Termination | Customized |
The 132C + 40AWG + High Capacitance combination should remain clearly visible on the page as the product's primary technical identity.
132-Core Configuration Considerations
A 132-core cable requires clear electrical mapping before production.
Engineering teams should define:
For a high-core-count probe cable, the recommended RFQ package is:
Cable Drawing + Wiring Diagram + Connector Drawing + Pinout
This allows the supplier to control conductor allocation and termination accurately.
40AWG Fine-Gauge Conductor Considerations
The 40AWG conductor size supports dense multi-core cable construction.
Customers should specify:
The conductor size should be considered together with the 132-core configuration because the overall cable diameter and flexibility depend on the complete construction.
High-Capacitance Considerations
High capacitance is a defining electrical characteristic of this product and should be treated as an engineering specification rather than only a marketing term.
Customers should clarify:
The final capacitance depends on cable geometry and dielectric construction, so it should be evaluated together with the conductor and insulation structure.
Signal Integrity Considerations
For ultrasound probe assemblies, signal integrity should be evaluated across the complete transmission path.
Important parameters may include:
Where the ultrasound system has specific electrical acceptance criteria, those requirements should be included in the engineering drawing or RFQ.
Cable Diameter and Mechanical Routing
The finished OD of a 132-core cable depends on:
132-Core Count + 40AWG + Insulation + Shielding + Outer Construction
Customers should define:
For a high-density ultrasound probe cable, cable diameter and core count need to be balanced during the design stage.
Flexibility Considerations
Ultrasound probe cables may experience repeated movement during examination and handling.
Engineering teams should specify:
The complete 132-core structure should maintain its electrical characteristics while meeting the mechanical movement requirements.
Shielding and EMI Considerations
Whether individual or overall shielding is required should be determined by the ultrasound system architecture.
Customers should specify:
For high-density ultrasound cables, shielding and grounding should be evaluated together with capacitance and signal requirements.
Handle Connection Considerations
Because the product is positioned as a handle connection cable assembly, the mechanical interface between cable and handle should be confirmed carefully.
Important considerations include:
The cable should be designed around the actual handle geometry rather than selected only from the electrical specification.
Connector and Termination Considerations
For a 132-core ultrasound cable, termination is a critical part of the complete assembly.
Customers should provide:
A complete pinout is especially important for a 132-core configuration.
Key Procurement Parameters
When sourcing a 132C 40AWG high-capacitance ultrasound cable assembly, procurement teams should confirm:
| Procurement Item | Recommended Information |
|---|---|
| Application | Medical Ultrasound / B-Ultrasound |
| Cable Type | Ultrasound Probe / Handle Connection Cable Assembly |
| Core Count | 132C |
| Conductor Size | 40AWG |
| Conductor Material | Required material / plating |
| Capacitance | High-capacitance target and tolerance |
| Insulation | Required material |
| Shielding | Required shield structure |
| Cable Diameter | Target / maximum allowable OD |
| OD Tolerance | Required tolerance |
| Cable Length | Finished cable length |
| Flexibility | Bending / routing requirements |
| Connector | Probe-side / handle-side / equipment-side connector |
| Pinout | Channel and contact assignment |
| Termination | Required termination method |
| Drawing | Cable / assembly drawing |
| Prototype Quantity | Engineering sample quantity |
| Production Volume | Expected recurring volume |
| Testing | Capacitance, continuity, dimensional and mechanical requirements |
OEM Customization
HOTTEN supports customized ultrasound probe cable assemblies according to customer drawings and system requirements.
Customization may include:
For OEM projects, the final cable should be developed around the customer's ultrasound probe and handle architecture rather than treated as a generic 132-core cable.
Supplier Evaluation Checklist
When evaluating a supplier for a 132C high-capacitance ultrasound cable, procurement teams should consider:
① High-Core-Count Manufacturing
Can the supplier consistently manufacture and terminate 132-core cable configurations?
② Fine-Gauge Processing
Can the supplier reliably process 40AWG conductors across a high-core-count structure?
③ Capacitance Control
Can the supplier control the specified capacitance and maintain consistency across channels?
④ Ultrasound Cable Capability
Does the supplier have experience manufacturing probe and transducer cables?
⑤ Connector Assembly
Can the supplier accurately manage high-density connector pinout and termination?
⑥ Mechanical Performance
Can the supplier maintain flexibility and dimensional stability during repeated probe handling?
⑦ Prototype-to-Mass-Production Support
Can the supplier support engineering samples and recurring production?
Recommended RFQ Information
For faster engineering evaluation and quotation, customers are recommended to provide:
For this product, the most important RFQ combination is:
132C + 40AWG + High Capacitance + Cable OD + Cable Length + Connector + Pinout + Electrical Requirements
HOTTEN 132-Core Ultrasound Cable Engineering Support
HOTTEN provides customized high-density medical ultrasound probe cable assemblies for B-ultrasound and related diagnostic applications.
This product is differentiated by its 132-core, 40AWG, high-capacitance handle-connection configuration, providing a specific cable architecture for ultrasound probe systems requiring a large number of electrical channels within one assembly.
For OEM development, customers can provide the ultrasound probe specification, capacitance requirement, cable drawing, connector information and pinout for engineering evaluation and customized production.




◆ Customization Options
HOTTEN supports customized ultrasound cable development according to customer requirements.
Available customization includes:
✓ Core number
✓ AWG conductor size
✓ Cable length
✓ Shielding structure
✓ Insulation materials
✓ Outer jacket materials
Common material options include:
● PTFE
● FEP
● PFA
● Silicone
● TPU
● PVC
◆ Why Choose HOTTEN
HOTTEN specializes in micro coaxial cables and customized medical cable assemblies.
Our capabilities include:
✓ Ultra-fine wire processing
✓ Micro coaxial cable manufacturing
✓ Precision extrusion
✓ Cable structure optimization
✓ Prototype development and mass production
We support medical equipment manufacturers with reliable cable solutions from initial design to production.
◆ FAQ
What is a 132 core ultrasound cable?
A 132 core ultrasound cable is a high-density cable containing multiple signal channels, designed for ultrasound probes and medical imaging equipment requiring complex signal transmission.
What is the difference between 40AWG and 42AWG ultrasound cables?
40AWG cables provide a different balance between conductor size, mechanical strength and electrical performance, while 42AWG cables are typically optimized for smaller diameter and higher-density applications.
Can HOTTEN customize ultrasound probe cable assemblies?
Yes. HOTTEN provides customized ultrasound cable assemblies including conductor specifications, core numbers, shielding design and jacket materials.