Hotten 12C(12X36AWG) B Ultrasound Cable 36AWG 12 Cores OD5.3mm Medical Wire Cable Endoscope/B Ultrasound Cable Wire
|
Constitute
|
12C(12X36AWG) Medical Endoscope Handle Cable
|
|
Place of Origin
|
China,Jiangsu
|
|
Brand Name
|
Hotten Cable
|
|
Pins/cores(Customizable)
|
12C(3C/5C/7C /9C/10C/11C/12C/14C...)
|
|
Cable AWG
|
36AWG(30AWG...38AWG,40AWG,42AWG,44AWG,46AWG,48AWG)
|
|
Jacket
|
PFA(PVC,Silicone,TPE,TPU)
|
|
Color
|
Gray/White/Black/Ivory(Customizable)
|
|
Outer Diameter
|
5.3mm(0.1mm-20mm)
|
|
Length
|
Customized Length
|
|
Certification
|
ROHS、REACH、ISO13485、UL、ISO9001
|
|
Application
|
Medical Endoscope,Industrial Endoscope ,Test Equipment
|
- Overview
- Recommended Products
- Wire Size: 36AWG
- Core Configuration: 12C
- Outer Diameter: 5.3mm
- PVC
- TPU
- Silicone
Ultrasound signal channels
Power conductors
Ground / return conductors
Control lines
Auxiliary electrical connections
Core count
Core arrangement
Conductor size
Conductor material
Pin assignment
Grounding configuration
Connector interface
36AWG or alternative conductor size
Conductor material
Plating requirements
Stranding structure
Insulation
Required flexibility
Electrical characteristics
Target OD
Maximum allowable OD
OD tolerance
Probe or handle installation space
Connector entry dimensions
Strain-relief dimensions
Routing path
Required bending radius
Number of signal channels
Cable length
Conductor configuration
Signal requirements
Capacitance requirements, where specified
Grounding
Connector interface
Probe-side termination
Handle routing
Available installation space
Cable flexibility
Connector position
Repeated bending
Cable entry direction
Strain relief
Mechanical interference with surrounding components
Minimum bending radius
Repeated flexing
Handle movement
Probe movement
Internal routing
Strain relief
Assembly conditions
Signal sensitivity
Electromagnetic environment
Conductor arrangement
Grounding method
Cable length
Connector termination
Channel-to-channel interference
Core count
Core configuration
AWG
Conductor material
Insulation
Shielding
Cable diameter
Cable length
Jacket material
Connector type
Pin assignment
Termination
Prototype samples
Mass-production configuration
Application: B-ultrasound or endoscope
Required core count
36AWG or other conductor size
Conductor material
Cable drawing
Target OD
OD tolerance
Insulation requirement
Shielding requirement
Jacket requirement
Cable length
Flexibility / bending requirement
Connector part number
Pinout
Termination drawing
Prototype quantity
Expected production volume
Required testing
Applicable quality requirements
Product Overview
12C 36AWG B Ultrasound Probe Cable
HOTTEN 12C 36AWG B Ultrasound Probe Cable is designed for medical ultrasound transducer systems requiring reliable signal transmission, flexible structure and compact cable dimensions.
With a 12-core 36AWG configuration and optimized cable diameter, this cable provides a practical solution for B-ultrasound probes and medical imaging equipment where flexibility and stable performance are required.
HOTTEN supports customized ultrasound cable development including conductor size, core number, shielding structure, outer diameter, jacket material and cable assembly according to customer requirements.
Key Features
Flexible Cable Solution for Ultrasound Imaging Systems
🔹 12-core ultrasound cable structure
🔹 36AWG fine conductor design
🔹 Compact OD 5.3mm cable diameter
🔹 Flexible construction for probe movement
🔹 Reliable signal transmission performance
🔹 Customized specifications available
Cable Structure
Precision Design for Medical Probe Applications
Typical specification:
Conductor
Cable Diameter
Jacket Material
Options:
Customized Options
Available:
✔ Core Number
✔ AWG Size
✔ Shielding Structure
✔ Outer Diameter
✔ Cable Length
✔ Connector Assembly
Applications
Medical Ultrasound & Diagnostic Equipment
Suitable for:
🏥 B-Ultrasound Systems
🏥 Ultrasound Probe Equipment
🏥 Medical Diagnostic Imaging Devices
🏥 Transducer Systems
🏥 OEM Medical Equipment
Customization Options
HOTTEN provides customized ultrasound cable solutions:
✔ Cable Structure Design
✔ Core Configuration
✔ Conductor Material
✔ Wire Gauge
✔ Insulation Material
✔ Shielding Solution
✔ Cable Diameter
✔ Connector Assembly






Engineering & Procurement Considerations
What Engineers Should Consider When Selecting a 12C 36AWG Ultrasound Cable
A 12-core ultrasound cable is used to connect an ultrasound probe, transducer or related imaging component with the supporting medical equipment. This configuration combines 12 × 36AWG conductors with a 5.3mm outer diameter, providing a defined multi-core structure for B-ultrasound and related medical cable applications.
For medical ultrasound and endoscope equipment, cable selection should consider core configuration, fine-gauge conductors, outer diameter, flexibility, signal transmission, shielding, connector compatibility and mechanical routing as one complete cable design.
Published Product Configuration
| Item | Specification |
|---|---|
| Product Type | Medical Ultrasound Cable |
| Application | B Ultrasound / Endoscope |
| Core Configuration | 12C |
| Conductor Configuration | 12 × 36AWG |
| Outer Diameter | 5.3mm |
| Cable Structure | Multi-Core Medical Cable |
| Cable Length | Customized |
| Connector / Termination | Customized |
| Jacket Material | According to product configuration / customer requirement |
The 12C, 12×36AWG and 5.3mm OD values are the main configuration entities represented by the product listing.
Key Engineering Requirements
| Engineering Requirement | Key Considerations |
|---|---|
| 12-Core Configuration | The number of conductors should match the required signal, power and auxiliary channels of the target ultrasound or endoscope system. |
| 36AWG Fine-Gauge Construction | Fine-gauge conductors help support a compact multi-core cable structure. |
| 5.3mm Outer Diameter | OD should fit the available space in the probe, handle or equipment routing path. |
| Signal Transmission | Conductor structure, insulation and cable length should be matched to the electrical requirements of the system. |
| Flexibility | The cable should accommodate the required bending and routing conditions during equipment use and assembly. |
| Mechanical Reliability | Repeated handling and bending should be considered when selecting the cable construction. |
| Connector Compatibility | Connector type, pinout and termination should match the probe or equipment interface. |
| Manufacturing Consistency | Core configuration, cable dimensions and termination quality should remain consistent across production. |
12-Core Configuration Considerations
For a 12C cable, engineers should define the function of each conductor before production.
Potential conductor assignments may include:
The exact allocation must come from the customer's electrical schematic or cable drawing.
For procurement, the following information should be confirmed:
A detailed wiring diagram is recommended to avoid ambiguity during cable assembly development.
36AWG Conductor Considerations
The 12 × 36AWG configuration is an important technical identifier for this product.
Before production, customers should specify:
Fine-gauge conductor selection should be evaluated together with the complete cable construction because conductor size affects cable diameter, flexibility and manufacturing requirements.
5.3mm Outer Diameter Considerations
The published configuration specifies a 5.3mm outer diameter.
Engineers should define:
The 5.3mm value should therefore be treated as a product configuration reference, while the final acceptable tolerance should come from the customer's drawing.
B-Ultrasound Application Considerations
For B-ultrasound equipment, the cable should be evaluated according to the electrical requirements of the probe and diagnostic system.
Important inputs may include:
The cable should be designed as part of the ultrasound signal path rather than selected solely by core count.
Endoscope Application Considerations
The product listing also associates this cable configuration with endoscope applications.
For endoscope integration, engineers should additionally consider:
The same 12-core concept may require different construction details depending on whether the final application is B-ultrasound equipment or an endoscope assembly.
Flexibility and Routing
For medical cables used around probes, handles or movable equipment, flexibility can be an important mechanical requirement.
Procurement teams should define:
Core Count + OD + Cable Length + Flexibility + Bend Requirement
Important mechanical requirements may include:
A flexible cable construction should still maintain the required conductor and insulation integrity during repeated movement.
Shielding and Signal Considerations
Whether shielding is required should be determined from the customer's system architecture.
Engineers should consider:
The final shielding structure should be specified according to the customer's electrical requirements rather than assumed from the general product name.
Key Procurement Parameters
When sourcing this 12C 36AWG medical ultrasound cable, procurement teams should confirm:
| Procurement Item | Recommended Information |
|---|---|
| Application | B Ultrasound / Endoscope |
| Cable Type | Medical Ultrasound Cable |
| Core Count | 12C |
| Conductor Configuration | 12 × 36AWG |
| Conductor Material | Required material / plating |
| Insulation | Required insulation material |
| Shielding | Required shielding structure, if applicable |
| Outer Diameter | 5.3mm or specified OD |
| OD Tolerance | Required tolerance |
| Cable Length | Finished cable length |
| Flexibility | Required bending / routing characteristics |
| Jacket | Required jacket material |
| Connector | Connector model / part number |
| Pinout | Contact / channel assignment |
| Termination | Required termination method |
| Drawing | Cable / assembly drawing |
| Prototype Quantity | Engineering sample quantity |
| Production Volume | Expected recurring production volume |
| Testing | Electrical, dimensional and mechanical requirements |
OEM Customization
HOTTEN supports customization of medical ultrasound cable configurations according to customer requirements.
Customization may include:
For OEM projects, the cable should be developed around the actual ultrasound probe or endoscope architecture rather than treated as a generic 12-core cable.
Supplier Evaluation Checklist
When evaluating a supplier for a 12-core medical ultrasound cable, procurement teams should consider:
① Multi-Core Cable Capability
Can the supplier consistently manufacture and terminate 12-core fine-gauge cable?
② Fine-Gauge Processing
Can the supplier maintain stable 36AWG conductor and insulation dimensions?
③ Dimensional Control
Can the supplier maintain the required 5.3mm OD and tolerance?
④ Medical Application Experience
Does the supplier have experience with ultrasound or endoscope cable applications?
⑤ Connector Assembly
Can the supplier accurately manage the required connector and pinout?
⑥ Prototype-to-Mass-Production Support
Can the supplier support engineering samples and recurring production?
Recommended RFQ Information
For faster engineering evaluation and quotation, customers are recommended to provide:
For this configuration, the most important information to provide together is:
12C + 36AWG + 5.3mm OD + Application + Cable Length + Connector + Pinout
HOTTEN 12C Medical Ultrasound Cable Engineering Support
HOTTEN provides customized 12-core medical ultrasound cables for B-ultrasound and related endoscope applications. This product configuration is identified by 12C, 12×36AWG conductors and 5.3mm outer diameter, with the final cable construction and termination configurable according to the customer's requirements.
For OEM projects, customers can provide a cable drawing, connector specification and application requirements for technical evaluation and customized production.
Professional Ultrasound Cable Manufacturer
Medical Cable Development Capability
HOTTEN specializes in customized medical cables including ultrasound probe cables, micro coaxial cables and imaging cable solutions.
Flexible Manufacturing
Cable structures can be optimized according to space requirements, signal performance and mechanical flexibility.
OEM Customization Support
From prototype samples to mass production, HOTTEN provides complete cable manufacturing support.
FAQ
Q1: What equipment uses 12C ultrasound cables?
12C ultrasound cables are commonly used in B-ultrasound probes, medical transducers and diagnostic imaging equipment.
Q2: Can HOTTEN customize ultrasound cables with different core numbers?
Yes. HOTTEN supports customized core configurations according to customer signal and structural requirements.
Q3: What AWG sizes can be customized?
HOTTEN provides different fine wire solutions including 36AWG, 38AWG, 40AWG and other customized sizes.
Q4: Can HOTTEN provide complete cable assemblies?