+86-13912615597 [email protected]
All Categories
b ultrasound cable wire-0

Ultra Fine Medical Cable

Home >  Products >  Micro & Ultra Fine Cable >  Ultra Fine Medical Cable

Hotten 12C(12X36AWG) B Ultrasound Cable 36AWG 12 Cores OD5.3mm Medical Wire Cable Endoscope/B Ultrasound Cable Wire

Constitute
12C(12X36AWG) Medical Endoscope Handle Cable
Place of Origin
China,Jiangsu
Brand Name
Hotten Cable
Pins/cores(Customizable)
12C(3C/5C/7C /9C/10C/11C/12C/14C...)
Cable AWG
36AWG(30AWG...38AWG,40AWG,42AWG,44AWG,46AWG,48AWG)
Jacket
PFA(PVC,Silicone,TPE,TPU)
Color
Gray/White/Black/Ivory(Customizable)
Outer Diameter
5.3mm(0.1mm-20mm)
Length
Customized Length
Certification
ROHS、REACH、ISO13485、UL、ISO9001
Application
Medical Endoscope,Industrial Endoscope ,Test Equipment
  • Overview
  • Recommended Products
Products Description

Product Overview

12C 36AWG B Ultrasound Probe Cable

HOTTEN 12C 36AWG B Ultrasound Probe Cable is designed for medical ultrasound transducer systems requiring reliable signal transmission, flexible structure and compact cable dimensions.

With a 12-core 36AWG configuration and optimized cable diameter, this cable provides a practical solution for B-ultrasound probes and medical imaging equipment where flexibility and stable performance are required.

HOTTEN supports customized ultrasound cable development including conductor size, core number, shielding structure, outer diameter, jacket material and cable assembly according to customer requirements.


Key Features

Flexible Cable Solution for Ultrasound Imaging Systems

🔹 12-core ultrasound cable structure

🔹 36AWG fine conductor design

🔹 Compact OD 5.3mm cable diameter

🔹 Flexible construction for probe movement

🔹 Reliable signal transmission performance

🔹 Customized specifications available


Cable Structure

Precision Design for Medical Probe Applications

Typical specification:

Conductor

  • Wire Size: 36AWG
  • Core Configuration: 12C

Cable Diameter

  • Outer Diameter: 5.3mm

Jacket Material

Options:

  • PVC
  • TPU
  • Silicone

Customized Options

Available:

✔ Core Number

✔ AWG Size

✔ Shielding Structure

✔ Outer Diameter

✔ Cable Length

✔ Connector Assembly


Applications

Medical Ultrasound & Diagnostic Equipment

Suitable for:

🏥 B-Ultrasound Systems

🏥 Ultrasound Probe Equipment

🏥 Medical Diagnostic Imaging Devices

🏥 Transducer Systems

🏥 OEM Medical Equipment


Customization Options

HOTTEN provides customized ultrasound cable solutions:

✔ Cable Structure Design

✔ Core Configuration

✔ Conductor Material

✔ Wire Gauge

✔ Insulation Material

✔ Shielding Solution

✔ Cable Diameter

✔ Connector Assembly

b ultrasound cable wire-1
b ultrasound cable wire-2
b ultrasound cable wire-3
More Product Recommendations
b ultrasound cable wire-4
b ultrasound cable wire-5
Company Profile
b ultrasound cable wire-6
b ultrasound cable wire-7
b ultrasound cable wire-8
Production Process
b ultrasound cable wire-9
Our Advantages
b ultrasound cable wire-10
Certifications
b ultrasound cable wire-11
Product packaging

Engineering & Procurement Considerations

What Engineers Should Consider When Selecting a 12C 36AWG Ultrasound Cable

A 12-core ultrasound cable is used to connect an ultrasound probe, transducer or related imaging component with the supporting medical equipment. This configuration combines 12 × 36AWG conductors with a 5.3mm outer diameter, providing a defined multi-core structure for B-ultrasound and related medical cable applications.

For medical ultrasound and endoscope equipment, cable selection should consider core configuration, fine-gauge conductors, outer diameter, flexibility, signal transmission, shielding, connector compatibility and mechanical routing as one complete cable design.

Published Product Configuration

Item Specification
Product Type Medical Ultrasound Cable
Application B Ultrasound / Endoscope
Core Configuration 12C
Conductor Configuration 12 × 36AWG
Outer Diameter 5.3mm
Cable Structure Multi-Core Medical Cable
Cable Length Customized
Connector / Termination Customized
Jacket Material According to product configuration / customer requirement

The 12C, 12×36AWG and 5.3mm OD values are the main configuration entities represented by the product listing.

Key Engineering Requirements

Engineering Requirement Key Considerations
12-Core Configuration The number of conductors should match the required signal, power and auxiliary channels of the target ultrasound or endoscope system.
36AWG Fine-Gauge Construction Fine-gauge conductors help support a compact multi-core cable structure.
5.3mm Outer Diameter OD should fit the available space in the probe, handle or equipment routing path.
Signal Transmission Conductor structure, insulation and cable length should be matched to the electrical requirements of the system.
Flexibility The cable should accommodate the required bending and routing conditions during equipment use and assembly.
Mechanical Reliability Repeated handling and bending should be considered when selecting the cable construction.
Connector Compatibility Connector type, pinout and termination should match the probe or equipment interface.
Manufacturing Consistency Core configuration, cable dimensions and termination quality should remain consistent across production.

12-Core Configuration Considerations

For a 12C cable, engineers should define the function of each conductor before production.

Potential conductor assignments may include:

  • Ultrasound signal channels

  • Power conductors

  • Ground / return conductors

  • Control lines

  • Auxiliary electrical connections

The exact allocation must come from the customer's electrical schematic or cable drawing.

For procurement, the following information should be confirmed:

  • Core count

  • Core arrangement

  • Conductor size

  • Conductor material

  • Pin assignment

  • Grounding configuration

  • Connector interface

A detailed wiring diagram is recommended to avoid ambiguity during cable assembly development.

36AWG Conductor Considerations

The 12 × 36AWG configuration is an important technical identifier for this product.

Before production, customers should specify:

  • 36AWG or alternative conductor size

  • Conductor material

  • Plating requirements

  • Stranding structure

  • Insulation

  • Required flexibility

  • Electrical characteristics

Fine-gauge conductor selection should be evaluated together with the complete cable construction because conductor size affects cable diameter, flexibility and manufacturing requirements.

5.3mm Outer Diameter Considerations

The published configuration specifies a 5.3mm outer diameter.

Engineers should define:

  • Target OD

  • Maximum allowable OD

  • OD tolerance

  • Probe or handle installation space

  • Connector entry dimensions

  • Strain-relief dimensions

  • Routing path

  • Required bending radius

The 5.3mm value should therefore be treated as a product configuration reference, while the final acceptable tolerance should come from the customer's drawing.

B-Ultrasound Application Considerations

For B-ultrasound equipment, the cable should be evaluated according to the electrical requirements of the probe and diagnostic system.

Important inputs may include:

  • Number of signal channels

  • Cable length

  • Conductor configuration

  • Signal requirements

  • Capacitance requirements, where specified

  • Grounding

  • Connector interface

  • Probe-side termination

The cable should be designed as part of the ultrasound signal path rather than selected solely by core count.

Endoscope Application Considerations

The product listing also associates this cable configuration with endoscope applications.

For endoscope integration, engineers should additionally consider:

  • Handle routing

  • Available installation space

  • Cable flexibility

  • Connector position

  • Repeated bending

  • Cable entry direction

  • Strain relief

  • Mechanical interference with surrounding components

The same 12-core concept may require different construction details depending on whether the final application is B-ultrasound equipment or an endoscope assembly.

Flexibility and Routing

For medical cables used around probes, handles or movable equipment, flexibility can be an important mechanical requirement.

Procurement teams should define:

Core Count + OD + Cable Length + Flexibility + Bend Requirement

Important mechanical requirements may include:

  • Minimum bending radius

  • Repeated flexing

  • Handle movement

  • Probe movement

  • Internal routing

  • Strain relief

  • Assembly conditions

A flexible cable construction should still maintain the required conductor and insulation integrity during repeated movement.

Shielding and Signal Considerations

Whether shielding is required should be determined from the customer's system architecture.

Engineers should consider:

  • Signal sensitivity

  • Electromagnetic environment

  • Conductor arrangement

  • Grounding method

  • Cable length

  • Connector termination

  • Channel-to-channel interference

The final shielding structure should be specified according to the customer's electrical requirements rather than assumed from the general product name.

Key Procurement Parameters

When sourcing this 12C 36AWG medical ultrasound cable, procurement teams should confirm:

Procurement Item Recommended Information
Application B Ultrasound / Endoscope
Cable Type Medical Ultrasound Cable
Core Count 12C
Conductor Configuration 12 × 36AWG
Conductor Material Required material / plating
Insulation Required insulation material
Shielding Required shielding structure, if applicable
Outer Diameter 5.3mm or specified OD
OD Tolerance Required tolerance
Cable Length Finished cable length
Flexibility Required bending / routing characteristics
Jacket Required jacket material
Connector Connector model / part number
Pinout Contact / channel assignment
Termination Required termination method
Drawing Cable / assembly drawing
Prototype Quantity Engineering sample quantity
Production Volume Expected recurring production volume
Testing Electrical, dimensional and mechanical requirements

OEM Customization

HOTTEN supports customization of medical ultrasound cable configurations according to customer requirements.

Customization may include:

  • Core count

  • Core configuration

  • AWG

  • Conductor material

  • Insulation

  • Shielding

  • Cable diameter

  • Cable length

  • Jacket material

  • Connector type

  • Pin assignment

  • Termination

  • Prototype samples

  • Mass-production configuration

For OEM projects, the cable should be developed around the actual ultrasound probe or endoscope architecture rather than treated as a generic 12-core cable.

Supplier Evaluation Checklist

When evaluating a supplier for a 12-core medical ultrasound cable, procurement teams should consider:

① Multi-Core Cable Capability
Can the supplier consistently manufacture and terminate 12-core fine-gauge cable?

② Fine-Gauge Processing
Can the supplier maintain stable 36AWG conductor and insulation dimensions?

③ Dimensional Control
Can the supplier maintain the required 5.3mm OD and tolerance?

④ Medical Application Experience
Does the supplier have experience with ultrasound or endoscope cable applications?

⑤ Connector Assembly
Can the supplier accurately manage the required connector and pinout?

⑥ Prototype-to-Mass-Production Support
Can the supplier support engineering samples and recurring production?

Recommended RFQ Information

For faster engineering evaluation and quotation, customers are recommended to provide:

  • Application: B-ultrasound or endoscope

  • Required core count

  • 36AWG or other conductor size

  • Conductor material

  • Cable drawing

  • Target OD

  • OD tolerance

  • Insulation requirement

  • Shielding requirement

  • Jacket requirement

  • Cable length

  • Flexibility / bending requirement

  • Connector part number

  • Pinout

  • Termination drawing

  • Prototype quantity

  • Expected production volume

  • Required testing

  • Applicable quality requirements

For this configuration, the most important information to provide together is:

12C + 36AWG + 5.3mm OD + Application + Cable Length + Connector + Pinout

HOTTEN 12C Medical Ultrasound Cable Engineering Support

HOTTEN provides customized 12-core medical ultrasound cables for B-ultrasound and related endoscope applications. This product configuration is identified by 12C, 12×36AWG conductors and 5.3mm outer diameter, with the final cable construction and termination configurable according to the customer's requirements.

For OEM projects, customers can provide a cable drawing, connector specification and application requirements for technical evaluation and customized production.

Professional Ultrasound Cable Manufacturer

Medical Cable Development Capability

HOTTEN specializes in customized medical cables including ultrasound probe cables, micro coaxial cables and imaging cable solutions.

Flexible Manufacturing

Cable structures can be optimized according to space requirements, signal performance and mechanical flexibility.

OEM Customization Support

From prototype samples to mass production, HOTTEN provides complete cable manufacturing support.


FAQ

Q1: What equipment uses 12C ultrasound cables?

12C ultrasound cables are commonly used in B-ultrasound probes, medical transducers and diagnostic imaging equipment.


Q2: Can HOTTEN customize ultrasound cables with different core numbers?

Yes. HOTTEN supports customized core configurations according to customer signal and structural requirements.


Q3: What AWG sizes can be customized?

HOTTEN provides different fine wire solutions including 36AWG, 38AWG, 40AWG and other customized sizes.


Q4: Can HOTTEN provide complete cable assemblies?

Yes. Cable assembly and connector integration services are available according to customer drawings.

Get a Free Quote

Our representative will contact you soon.
Email
Phone number
Company Name
Message
0/1000

If you have any suggestions, please contact us

CONTACT US

Get a Free Quote

Our representative will contact you soon.
Email
Phone number
Company Name
Message
0/1000
b ultrasound cable wire-12 b ultrasound cable wire-13 b ultrasound cable wire-14 b ultrasound cable wire-15 b ultrasound cable wire-16